One Stop Tech Warehouse - Email us: info@polartech.com.au

Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester
Load image into Gallery viewer, [LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester

[LC1020E] FNIRSI High Precision Handheld Digital Bridge LCR ESR Tester

Regular price $120.00 AUD
Sale price $120.00 AUD Regular price
Sale Sold out
Unit price
/per 
Tax included. Shipping calculated at checkout.
Caution: This is a pre-order item. We will ship it out around 1-2 weeks

Highlights

High Accuracy Measurement: Up to ±0.05% accuracy with 4.5-digit resolution for professional-grade testing

Automatic R/L/C Identification for fast and efficient component measurement

Flexible Test Settings: 5 test frequencies (100 Hz–100 kHz) and 3 voltage levels (0.1 V–0.6 V)

Dual-Parameter Display: Simultaneous readout of L / C / R / Z with X / D / Q / θ / ESR for complete analysis

Sorting Mode & Built-in Bias Voltage for stable and efficient batch testing

Dual Test Interfaces: 3-terminal & 5-terminal ports with 4-wire Kelvin measurement support for high precision

Data Hold & Logging Functions to enhance testing efficiency and workflow

Compact, Rechargeable Design: Built-in 3000 mAh battery, ideal for laboratory, production, and field applications

Features:

  • High-Precision Measurement with 4.5-Digit Resolution
    Achieves up to ±0.05% basic accuracy, offering 10× improved precision for professional-grade measurements.

  • Wide Parameter Support
    Measures L/C/R/Z values with automatic mode switching, and displays X/D/Q/θ/ESR as secondary parameters for comprehensive component analysis.

  • Smart Auto Component Identification
    Automatically recognizes R/L/C components and switches modes instantly — ensuring fast and efficient testing with minimal manual input.

  • Multi-Frequency & Test Voltage Selection
    Supports 5 test frequencies: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Offers 3 RMS test levels: 0.1V, 0.3V, 0.6V — providing precise control across different testing scenarios.

  • Sorting & Comparison Function
    Set nominal values and tolerances (0.1%–99.9%) for automatic pass/fail judgment, with audio-visual prompts for fast batch testing and quality control.

  • Internal Bias Voltage
    Built-in bias voltage stabilizes readings and enhances measurement accuracy for sensitive components.

  • Dual Test Ports: 3-Terminal & 5-Terminal (4-Wire Kelvin)
    Ensures both ease of use and maximum accuracy by minimizing lead resistance error.

  • Dual-Parameter Display on 2.8" TFT Screen
    Clearly shows both main and secondary parameters in real time — easy to read anytime, anywhere.

  • Open & Short Calibration
    Calibrate test fixtures and eliminate system errors for accurate and repeatable results.

  • Data Hold & Logging Mode
    Short press to hold reading, long press to enter logging mode — with categorized statistics on pass/fail results for improved test efficiency.

  • Compact & Rechargeable Design
    Lightweight, portable body powered by a 3.7V 3000mAh lithium battery, perfect for lab, production line, and field use.

Specifications

General Parameters

  • Model: LC1020E

  • Display: 2.8-inch TFT LCD

  • Display Resolution:

    • Main Parameter: 4.5 digits

    • Secondary Parameter: 4.5 digits

  • Basic Accuracy: 0.3%


Measurement Specifications

  • Test Frequencies: 100 Hz / 120 Hz / 1 kHz / 10 kHz / 100 kHz

  • Measurement Parameters:

    • Main Parameters: AUTO / R / C / L / Z

    • Secondary Parameters: X / D / Q / θ / ESR

  • Measurement Ranges:

    • Inductance (L): 0 – 100 H

    • Capacitance (C): 0 – 100 mF

    • Resistance (R): 0 – 10 MΩ


Test Conditions

  • Test Levels: 0.1 V / 0.3 V / 0.6 V

  • Internal Bias Voltage: 0.0 V / 0.5 V

  • Output Impedance: 100 Ω


Calibration & Comparison Functions

  • Calibration: Open-circuit calibration, Short-circuit calibration

  • Comparison Function:
    Calculates the relative error between the measured value and the nominal value, displayed as a percentage.

    • Nominal value and tolerance are user-configurable

    • Tolerance range: 0.1% – 99.9%

    • Provides pass/fail sorting results

  • Function Record:
    Determines whether measured component data meets the preset nominal value and tolerance, and records pass and fail counts


Interface & Connectivity

  • Test Terminals: Three-terminal / Five-terminal

  • Communication Interface: USB Type-C (Virtual Serial Port)


System & Other Functions

  • Language selection

  • Screen brightness adjustment

  • Sound settings

  • Auto power-off

  • Calibration settings

  • System information

Measurement Accuracy:

⚠ Precautions:

  • The ambient temperature should be maintained at 20℃ ± 2℃, and the humidity should be ≤ 80% R.H.
  • The instrument should be preheated for at least 30 minutes before testing.
  • Testing should be performed at the instrument's test slots on the front panel.
  • It is recommended to perform open-circuit and short-circuit calibration before testing.

Package List:

◉ LC1020E LCR Meter *1
◉ Data Cable *1
◉ Shorting Plate *1
◉ Kelvin Test Clip *1
◉ Test Leads (Black *1 + Red *1)
◉ User Manual *1